Sound insulation |
Pod is leaking sound. |
A gap between back glasses. |
Push the glasses
together. |
A gap between side frame seal and threshold seal. |
Replace the seals. |
The seal between the frontside glasses and frames is too
short. |
Stretch the seal
and reinstall it. |
Floor of the pod is not level. |
Level the floor. |
Pod is not standing straight. |
Straighten the
pod. |
Door |
Door is difficult to close |
Seals are on the wrong side. |
Remove the seals and install them on the inside of the
pod. |
Side frame seal and threshold seal overlap. |
Cut
the threshold seal to the correct length. |
Threshold installed too far out. |
Reinstall the floor
threshold. |
Floor of the pod is not level. |
Level the floor.. |
Pod is not standing straight. |
Straighten the
pod. |
No adjustment plate under the lower hinge. |
Install an adjustment plate under the lower hinge. |
Power issues |
No electricity in the pod. |
Pod power cord not connected. |
Check that the pod power cord is connected to a power
outlet. |
Pod power cord is connected to a faulty power
outlet. |
Connect the pod power cord to another power
outlet. |
Loose connections under the floor cover board. |
Check
connections under the floor cover board. |
ON/OFF switch of the power unit is in the "O" position. |
Turn the ON/OFF switch in the "I" position. |
Power outlet not working. |
Power outlet cord not connected. |
Check
connection to power unit. |
Fans and light |
Fans and light do not switch on. |
Faulty motion detector. See Diagnose a faulty motion detector. |
Contact Framery Framery support for a replacement part. |
Loose connections in the control unit. |
Check
connections to control unit. |
Loose connections under the floor cover board. |
Check
connections under the floor cover board. |
Light not working. |
Light cord not connected to control unit. |
Check
connections to control unit. |
Fans not working. |
Fan cord not connnected to control unit. |
Check
connections to control unit. |
Fan modules' connections are loose. |
Check fan modules'
connections. |
Noisy fans. |
Fan blades are obstructed. |
Check that
fan blades can move freely. |
Fan speed set to 100%. |
Reduce the fan
speed. |
Air inside the pod is not fresh. |
Pod is positioned in direct sunlight, under a heating duct, or close
to some other heat source. Or, there is not enough space around or above
the pod. See Operating space. |
(For pods equipped with the casters.) Move the pod to another
location. |
Top of turnable table is loose. |
Screw under tabletop is loose. |
Reinstall the