Framery Q Troubleshooting

Issue Cause Solution
Sound insulation
Pod is leaking sound. A gap between back glasses. Push the glasses together.
A gap between side frame seal and threshold seal. Replace the seals.
The seal between the frontside glasses and frames is too short. Stretch the seal and reinstall it.
Floor of the pod is not level. Level the floor.
Pod is not standing straight. Straighten the pod.
Door
Door is difficult to close Seals are on the wrong side. Remove the seals and install them on the inside of the pod.
Side frame seal and threshold seal overlap. Cut the threshold seal to the correct length.
Threshold installed too far out. Reinstall the floor threshold.
Floor of the pod is not level. Level the floor..
Pod is not standing straight. Straighten the pod.
No adjustment plate under the lower hinge. Install an adjustment plate under the lower hinge.
Power issues
No electricity in the pod. Pod power cord not connected. Check that the pod power cord is connected to a power outlet.
Pod power cord is connected to a faulty power outlet. Connect the pod power cord to another power outlet.
Loose connections under the floor cover board. Check connections under the floor cover board.
ON/OFF switch of the power unit is in the "O" position. Turn the ON/OFF switch in the "I" position.
Power outlet not working. Power outlet cord not connected. Check connection to power unit.
Fans and light
Fans and light do not switch on. Faulty motion detector. See Diagnose a faulty motion detector. Contact Framery Framery support for a replacement part.
Loose connections in the control unit. Check connections to control unit.
Loose connections under the floor cover board. Check connections under the floor cover board.
Light not working. Light cord not connected to control unit. Check connections to control unit.
Fans not working. Fan cord not connnected to control unit. Check connections to control unit.
Fan modules' connections are loose. Check fan modules' connections.
Noisy fans. Fan blades are obstructed. Check that fan blades can move freely.
Fan speed set to 100%. Reduce the fan speed.
Air inside the pod is not fresh. Pod is positioned in direct sunlight, under a heating duct, or close to some other heat source. Or, there is not enough space around or above the pod. See Operating space. (For pods equipped with the casters.) Move the pod to another location.
Top of turnable table is loose. Screw under tabletop is loose. Reinstall the screw.